Sign In | Join Free | My himfr.com
Home > OLT >

AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU

 Fiberall Technology (Shenzhen) Co., Ltd
Contact Now
    Buy cheap AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU from wholesalers
     
    Buy cheap AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU from wholesalers
    • Buy cheap AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU from wholesalers
    • Buy cheap AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU from wholesalers
    • Buy cheap AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU from wholesalers

    AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU

    Ask Lasest Price
    Brand Name : Fiberall or OEM
    Model Number : FA-GOLT8608
    Certification : CE-RED
    Price : On request
    Payment Terms : L/C, T/T, Western Union, MoneyGram, PayPal
    Delivery Time : 4-7 days
    • Product Details
    • Company Profile

    AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU

    GPON OLT Optical Line Terminal For ONU With 8 PON 8 Gigabit Ethernet Ports

    How OLT To Distinguish Uplink Data From Different ONT ?

    The downlink data is simple for ONT because they are broadcast down from OLT, ONT only need to apart the information for itself from all information. However, the upstream flow is different, because the upstream flow will meet problem of information conflict .

    The former PON technology adopted TDMA for uplink , the time have to be divided then ONT can distinguish the uploaded data. So how ONT know to send the data? And how it know how long will it take to send the data? This requires an agreement between OLT and ONT to achieve the above functions. What will happen if the OLT assign a long time for the ONT? If the amount of data sent by ONT is relatively large, that is to say, the bandwidth of ONT is relatively large. And the ONT start to send data on the allocated time. However, it will waste the bandwidth when the ONT do not have data to send during the allocate time so other ONT which has large data to send can not use the same time . This situation will inevitably bring rising costs. So GPON allocate bandwidth based on T-CONT.

    With T-CONT, OLT is able to allocate bandwidth based on T-CONT. Of course, one ONT has multiple T-CONT, the benefits is it is able to allocate different type of T-CONT according to the different requirements of the business bandwidth. So T-CONT should have different types, currently there are four basic types of T-CONT: Fix, Assure, Not Assure and Best Effort (Max). They are used to represent different bandwidth allocation policies. What is the difference between them? To describe the difference, DBA has to be mentioned and please refer to another article in our website, Dynamically Bandwidth Assignment of OLT.

    Business Features

    1. Attributes
    FA-GOLT8608

    PON features

    GPON

    Satisfy ITU -T standard
    TR-101 compliant solution for FTTx OLT applications
    High splitter rate, each PON port supports 128*ONU ,
    Maximum transmission distance of 20KM
    Support uplink FEC, downlink FEC(Forward Error Correction)
    ONU identifier authentication :SN /SN+PASSWD
    Bandwidth allocation mechanism
    5 types of T-CONT bandwidth
    Static Bandwidth Allocation
    Dynamic Bandwidth Allocation
    GPON feature parameter
    4096 port-IDs per GPON MAC (Downstream and Upstream)
    1024 Alloc -IDs per GPON MAC (Upstream )

    L2 featuresMAC

    MAC Black Hole
    Port MAC Limit

    VLAN

    4K VLAN entries
    Port-based/MAC-based/IP subnet-based VLAN
    Port-based QinQ and Selective QinQ (StackVLAN)
    VLAN Swap and VLAN Remark and VLAN Translate
    GVRP
    Based on ONU service flow VLAN add, delete, replace

    Spanning tree protocol

    IEEE 802.1D Spanning Tree Protocol (STP)
    IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
    IEEE 802.1s Multiple Spanning Tree Protocol instances (MSTP)

    Port

    Bi-directional bandwidth control
    Static link aggregation and LACP(Link Aggregation Control Protocol)
    Port mirroring and traffic mirroring

    Security featuresUser security

    Anti-ARP-spoofing
    Anti-ARP-flooding
    IP Source Guard create IP+VLAN+MAC+Port binding
    Port Isolation
    MAC address binds to port and port MAC address filtration
    IEEE 802.1x and AAA/Radius authentication
    TACACS+ authentification
    dhcp anti-attack flood attack automatic suppression
    ONU isolation control

    Device security

    Anti-DOS attack(such as ARP,Synflood, Smurf, ICMP attack), ARP detection, worm and Msblaster worm attack
    SSHv2 Secure Shell
    SNMP v3 encrypted management
    Security IP login through Telnet
    Hierarchical management and password protection of users

    Network security

    User-based MAC and ARP traffic examination
    Restrict ARP traffic of each user and force-out user with abnormal ARP traffic
    Dynamic ARP table-based binding
    Supports IP+VLAN+MAC+Port binding
    L2 to L7 ACL flow filtration mechanism on the 80 bytes of the head of user-defined packet
    Port-based broadcast/multicast suppression and auto-shutdown risk port
    URPF to prevent IP address counterfeit and attack
    DHCP Option82 and PPPoE+ upload user’s physical location
    Plaintext authentication of OSPF,RIPv2 and MD5 cryptograph authentication

    IP routingIPv4ARP Proxy,DHCP Relay,DHCP Server,Static route
    IPv6

    ICMPv6,ICMPv6 redirection,DHCPv6,ACLv6,Configured Tunnel,6to4 tunnel
    IPv6 and IPv4 Tunnels

    Service featuresACL

    Standard and extended ACL
    Time Range ACL
    Packet filter providing filtering based on source/destination MAC address, source/destination IP address, port, protocol, VLAN, VLAN range, MAC address range, or invalid frame. System supports concurrent identification at most 50 service traffic
    Support packet filtration of L2~L7 even deep to 80 bytes of IP packet head

    QoS

    Rate-limit to packet sending/receiving speed of port or self-defined flow and provide general flow monitor and two-speed tri-color monitor of self-defined flow
    Priority remark to port or self-defined flow and provide 802.1P, DSCP priority and Remark
    CAR(Committed Access Rate),Traffic Shaping and flow statistics
    Packet mirror and redirection of interface and self-defined flow
    Super queue scheduler based on port and self-defined flow. Each port/ flow supports 8 priority queues and scheduler of SP, WRR and SP+WRR.
    Congestion avoid mechanism,including Tail-Drop and WRED

    Multicast

    IGMPv1/v2/v3 ,IGMPv1/v2/v3 Snooping
    IGMP Filter
    MVR and cross VLAN multicast copy
    IGMP Fast leave
    IGMP Proxy
    PIM-SM/PIM-DM/PIM-SSM
    PIM-SMv6,PIM-DMv6,PIM-SSMv6
    MLDv2/MLDv2 Snooping

    MPLSNPLS LDP
    ReliabilityLoop protection

    EAPS and GERP (recover-time <50ms)
    Loopback-detection

    Link protection

    FlexLink (recover-time <50ms)
    RSTP/MSTP (recover-time <1s)
    LACP (recover-time <10ms)
    BFD

    Device protection

    VRRP host backup
    Double fault-tolerant backup of host program and configuration files
    1+1 power hot backup

    MaintenanceNetwork maintenance

    Telnet-based statistics
    RFC3176 sFlow, LLDP
    802.3ah Ethernet OAM
    RFC 3164 BSD syslog Protocol
    Ping and Traceroute

    Device management

    Command-line interface(CLI), Console, Telnet and WEB configuration
    System configuration with SNMPv1/v2/v3
    RMON (Remote Monitoring)1/2/3/9 groups of MIB
    NTP(Network Time Protocol)


    Product Parameters Of FA-GOLT8608

    1. Attributes
    FA-GOLT8608
    Switching capacity102Gbps
    Throughput (IPv4/IPv6)75.88MPPS
    Ports4/8*PON port,8*GE FX+8*GE TX,2*10GE SFP+
    Power redundancyDual power supply. Can be double AC, double DC or AC+DC
    Power supply

    AC:Input 100~240V,47~63Hz;
    DC:Input -36V~-75V;

    Power consumption≤85W

    Outline dimensions
    (mm) (W*D*H)

    440mm×44mm×380mm
    Weight (in maximum configuration)≤3kg

    Environmental
    requirements

    Working temperature:-15°C~55°C
    Storage temperature:-40°C~70°C
    Relative humidity:10%~90%,no condensing






























































































    Quality AC / DC Power Supply Optical Line Terminal Equipment , GPON OLT Device For ONU for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To:  Fiberall Technology (Shenzhen) Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)